SmartPlug Systems (SmartPlug) is recalling certain 30A Shore Power Inlets, part number BM30xx manufactured From June 1, 2023, to July 21, 2023. The manganese bronze D-rings may crack or fail when over tightened.
SmartPlug Systems – Cracked D-ring in 30-Amp Inlet May Cause Failure
| Report Received Date | 08/01/2023 |
| NHTSA ID | 23E059000 |
| Consequence Summary | A D-ring that cracks or fails may allow wires to loosen, causing electrical arcing and increase the risk of a fire. |
| Corrective Action | Dealers will inspect and replace the SmartPlug 30-amp inlet as needed, free of charge. SmartPlug Systems notified customers July 24, 2023. Owners may contact SmartPlug customer service at email Warranty@smartPlug.com |
| Recall Code | NR (Not Reported) |
| Potentially Affected | 1248 |
| Fire Risk When Parked | No |
| Do Not Drive | No |
| Recall Link | Go to Recall (https://www.nhtsa.gov/recalls?nhtsaId=23E059000) |
More SmartPlug Systems Recalls