Winnebago Industries – ELECTRICAL SYSTEM:FUSE AND FUSE RECEPTICLE

A SOLDER BRIDGE ON THE PRINTED CIRCUIT BOARD WITHIN THE FUSE PANEL OF THE POWER CONVERTER PASSED UNDETECTED THROUGH A TEST FIXTURE AND BYPASSES THE FUSE PROTECTING THE CIRCUIT.


Report Received Date 10/12/1995
NHTSA ID 95E016005
Consequence Summary THIS SOLDER BRIDGE, WHEN COUPLED WITH A DEAD SHORTELSEWHERE IN THE SYSTEM, CAN RESULT IN CIRCUIT OVERLOAD, OVERHEATING, ANDEVEN FIRE, WITHOUT WARNING.
Corrective Action DETAILED TEST INSTRUCTIONS ARE BEING PROVIDED. IF A DEFECTIVE FUSE PANEL IS FOUND, A NEW REPLACEMENT PANEL WILL BE INSTALLED.
Recall Code NR (Not Reported)
Potentially Affected 7796
Fire Risk When Parked No
Do Not Drive No
Recall Link Go to Recall (https://www.nhtsa.gov/recalls?nhtsaId=95E016005)