Turtle Top – ELECTRICAL SYSTEM:FUSE AND FUSE RECEPTICLE

A SOLDER BRIDGE ON THE PRINTED CIRCUIT BOARD WITHIN THE FUSE PANEL OF THE POWER CONVERTER PASSED UNDETECTED THROUGH A TEST FIXTURE AND BYPASSES THE FUSE PROTECTING THE CIRCUIT.


Report Received Date 10/11/1995
NHTSA ID 95E016004
Consequence Summary THIS SOLDER BRIDGE, WHEN COUPLED WITH A DEAD SHORT ELSE WHERE IN THE SYSTEM, CAN RESULT IN CIRCUIT OVERLOAD, OVERHEATING, AND EVEN FIRE, WITHOUT WARNING.
Corrective Action DETAILED TEST INSTRUCTIONS ARE BEING PROVIDED. IF A DEFECTIVE FUSE PANEL IS FOUND, A NEW REPLACEMENT PANEL WILL BE INSTALLED.
Recall Code NR (Not Reported)
Potentially Affected 1
Fire Risk When Parked No
Do Not Drive No
Recall Link Go to Recall (https://www.nhtsa.gov/recalls?nhtsaId=95E016004)