Terex South Dakota – Ground Fault Interrupt Protection

Terex South Dakota (Terex) is recalling certain model year 2012 T292, TL, and NT Aerial Devices installed on utility trucks and equipped with a 110 VAC inverters. The Ground Fault Interrupt (GFI) may not offer GFI protection due to the neutral wire being ungrounded in the inverter.


Report Received Date 03/12/2013
NHTSA ID 13V088000
Consequence Summary If the GFI does not function, and a tool that is plugged into the inverter has a short, the operator could receive an electrical shock, resulting in electrocution.
Corrective Action Terex will notify owners, and dealers will add a jumper wire between the neutral and ground wire, free of charge. The recall began on April 18, 2013. Owners may contact Terex at 1-605-882-4000.
Recall Code SN605
Potentially Affected 23
Fire Risk When Parked No
Do Not Drive No
Recall Link Go to Recall (https://www.nhtsa.gov/recalls?nhtsaId=13V088000)