General Motors – Reprogram Sensing And Diagnostic Module

General Motors LLC (GM) is recalling certain model year 2013-2014 Cadillac XTS vehicles manufactured April 11, 2013, to June 27, 2013, and 2014 Chevrolet Impala vehicles manufactured May 13, 2013, to November 5, 2013. The affected vehicles may have left the factory with the sensing and diagnostic module (SDM) set to “manufacturing mode.”


Report Received Date 08/28/2014
NHTSA ID 14V518000
Consequence Summary In manufacturing mode, the vehicle's air bags will not deploy in the event of a crash, increasing the risk of occupant injury.
Corrective Action GM will notify owners, and dealers are to reprogram the SDM to the correct mode, free of charge. The recall is expected to begin in September 2014. Owners may contact Cadillac customer service at 1-800-458-8006 or Chevrolet customer service at 1-800-222-1020. GM's number for this recall is 14532.
Recall Code 14532
Potentially Affected 5
Fire Risk When Parked No
Do Not Drive No
Recall Link Go to Recall (https://www.nhtsa.gov/recalls?nhtsaId=14V518000)