AN ELECTRICAL SHORT CAN OCCUR IN THE AUXILLIARY HEATER/AIRCONDITIONING BLOWER IF EXPOSED TO WATER.
FREIGHTLINER LLC – FREIGHTLINER/ELECTRICAL
| Report Received Date | 10/08/1996 |
| NHTSA ID | 96V197000 |
| Consequence Summary | THE SHORTED RELAY CAN RESULT IN A FIRE. |
| Corrective Action | DEALERS WILL REMOVE AND REPLACE THE RELAY WITH ONE THAT RESISTS SHORTING IF CONTACTED BY WATER AND DOES NOT SUPPORT COMBUSTION EVEN IF SHORTED. |
| Recall Code | NR (Not Reported) |
| Potentially Affected | 3800 |
| Fire Risk When Parked | No |
| Do Not Drive | No |
| Recall Link | Go to Recall (https://www.nhtsa.gov/recalls?nhtsaId=96V197000) |